Weekly EHS Inspection
Subject: |
|
Inspection Date: |
|
Inspected By: |
|
Reviewed By: |
|
1. General
a. |
Personal protective equipment worn by workers/site staff (safety harness, helmet shoes, ear plug, repirator, etc) |
Locations |
|
Findings |
|
Remarks |
|
b. |
Safety information board and assembly stage provided |
Location |
|
Findings |
|
Remarks |
|
2. Scaffold
a. |
No missing cross bracing |
Location |
|
Findings |
|
Remarks |
|
b. |
No torn nettings |
Location |
|
Findings |
|
Remarks |
|
c. |
No accumulations of waste and construction debris at working platform |
Location |
|
Findings |
|
Remarks |
|
d. |
No missing toe board |
Location |
|
Findings |
|
Remarks |
|
e. |
Gaps between scaffold and building edge no more than 300mm where humans could fall |
Location |
|
Findings |
|
Remarks |
|
f. |
If the above mentioned gap is >300mm, working platform to be provided with toe boards and 2 or more guard rails |
Location |
|
Findings |
|
Remarks |
|
g. |
Working platform must be provided at every alternate lift |
Location |
|
Findings |
|
Remarks |
|
h. |
No single plank (less than 500mm width) |
Location |
|
Findings |
|
Remarks |
|
i. |
Scaffold erected at least 1m above construction level |
Location |
|
Findings |
|
Remarks |
|
j. |
Designated access to scaffold clearly marked |
Location |
|
Findings |
|
Remarks |
|
k. |
Proper signages on scaffolds and access points |
Location |
|
Findings |
|
Remarks |
|
l. |
Peripheral overhead shelter provided |
Location |
|
Findings |
|
Remarks |
|
m. |
Proper entry/exit points to the building under construction |
Location |
|
Findings |
|
Remarks |
|
n. |
Proper tie back provided as per PE design |
Location |
|
Findings |
|
Remarks |
|
3. Barricades
a. |
Barricade to open sides of buildings/scaffolds provided |
Location |
|
Findings |
|
Remarks |
|
b. |
Barricade to lift opening provided |
Location |
|
Findings |
|
Remarks |
|
c. |
Barricade and cover-up all openings in floor provided |
Location |
|
Findings |
|
Remarks |
|
4. Electrical hazards
a. |
Electrical wiring properly hand on insulated material |
Location |
|
Findings |
|
Remarks |
|
b. |
Approved type SOA used |
Location |
|
Findings |
|
Remarks |
|
c. |
Electrical wires/hand tools are in good condition |
Location |
|
Findings |
|
Remarks |
|
d. |
Welding machine an other electrical equipments are earthed |
Location |
|
Findings |
|
Remarks |
|
e. |
Temporary electrical wiring system checked by LEW monthly |
Location |
|
Findings |
|
Remarks |
|
f. |
Socket outlet assembly (SOA) must be totally enclosed and locked with no live terminal or parts exposed |
Location |
|
Findings |
|
Remarks |
|
5. Oxygen – fuel gas equipment
a. |
Implementation of permit to work system – hot work |
Location |
|
Findings |
|
Remarks |
|
b. |
Gas cylinder kept in up-right position and kept at a safe distance from heat sources |
Location |
|
Findings |
|
Remarks |
|
c. |
Hose connections clamped or securely fastened. No jubilee clip shall be used as a hose clamping device |
Location |
|
Findings |
|
Remarks |
|
d. |
Flashback arrestor fitted at the pressure regulator outlet of every gas cylinder |
Location |
|
Findings |
|
Remarks |
|
e. |
Non return valve fitted wbetween each gas torch inlet an gas hose |
Location |
|
Findings |
|
Remarks |
|
f. |
Fire extinguisher provided |
Location |
|
Findings |
|
Remarks |
|
6. Authorized persons
A. |
Machinery operated by authorized/competent person |
Location |
|
Findings |
|
Remarks |
|
b. |
P/M Hoists examined by AP at least once in 6/3 months |
Location |
|
Findings |
|
Remarks |
|
c. |
Gondola/mast platform examined by AP at least 6/3 months |
Location |
|
Findings |
|
Remarks |
|
7. Hoisting operation
a. |
Approved signaler/rigger/liftingsupervisor/crance operator to comply with lifting regulation |
Location |
|
Findings |
|
Remarks |
|
b. |
lifting gear and appliance examined by AP at least once in every 12/6 months |
Location |
|
Findings |
|
Remarks |
|
c. |
Proper access preparation for cranes and corrrect hoisting procedures (access checked by engineer) |
Location |
|
Findings |
|
Remarks |
|
8. Excavation
a. |
Excavation checklist submitted |
Location |
|
Findings |
|
Remarks |
|
b. |
Ladder provided if excavation exceed 1.2 metres in depth |
Location |
|
Findings |
|
Remarks |
|
c. |
Excavated area adequately shored if it is more than 1.5 metres deep |
Location |
|
Findings |
|
Remarks |
|
d. |
Open sides of excavation effectively barricade if it is more tha 1.5 metres deep |
Location |
|
Findings |
|
Remarks |
|
e. |
Materials placed at least 610mm back from the edge of open excavation |
Location |
|
Findings |
|
Remarks |
|
9. Water pollution control
a. |
Slit laden/slit trap used to reduce slit content; discharging only fresh water into the drain |
Location |
|
Findings |
|
Remarks |
|
b. |
Vehicular truck slit, mud, etc washed before leaving the site |
Location |
|
Findings |
|
Remarks |
|
10. General housekeeping and vector control
a. |
Step on/tripping hazard eliminated |
Location |
|
Findings |
|
Remarks |
|
b. |
Materials placed at least 1m away from edge of building |
Location |
|
Findings |
|
Remarks |
|
c. |
Access free from obstruction |
Location |
|
Findings |
|
Remarks |
|
d. |
No water-bearing receptacles |
Location |
|
Findings |
|
Remarks |
|
e. |
Ground is leveled properly, no depression |
Location |
|
Findings |
|
Remarks |
|
f. |
Mosquitoes breeding ground elimnated |
Location |
|
Findings |
|
Remarks |
|
g. |
Routine vector control is carried out |
Location |
|
Findings |
|
Remarks |
|
11. Others: ______________