Weekly EHS Inspection

Weekly EHS Inspection
Subject:                                                                                                                           
Inspection Date:  
Inspected By:  
Reviewed By:  

 

1. General

a. Personal protective equipment worn by workers/site staff (safety harness, helmet shoes, ear plug, repirator, etc)
Locations  
Findings  
Remarks  
b. Safety information board and assembly stage provided
Location  
Findings  
Remarks

2. Scaffold

a. No missing cross bracing
Location  
Findings  
Remarks  
b. No torn nettings
Location  
Findings  
Remarks
c. No accumulations of waste and construction debris at working platform
Location  
Findings  
Remarks  
d. No missing toe board
Location  
Findings  
Remarks
e. Gaps between scaffold and building edge no more than 300mm where humans could fall
Location  
Findings  
Remarks
f. If the above mentioned gap is >300mm, working platform to be provided with toe boards and 2 or more guard rails
Location  
Findings  
Remarks
g. Working platform must be provided at every alternate lift
Location  
Findings  
Remarks
h. No single plank (less than 500mm width)
Location  
Findings  
Remarks
i. Scaffold erected at least 1m above construction level
Location  
Findings  
Remarks
j. Designated access to scaffold clearly marked
Location  
Findings  
Remarks
k. Proper signages on scaffolds and access points
Location  
Findings  
Remarks
l. Peripheral overhead shelter provided
Location  
Findings  
Remarks
m. Proper entry/exit points to the building under construction
Location  
Findings  
Remarks
n. Proper tie back provided as per PE design
Location  
Findings  
Remarks


3. Barricades

a. Barricade to open sides of buildings/scaffolds provided
Location  
Findings  
Remarks
b. Barricade to lift opening provided
Location  
Findings  
Remarks
c. Barricade and cover-up all openings in floor provided
Location  
Findings  
Remarks

 

4. Electrical hazards

a. Electrical wiring properly hand on insulated material
Location  
Findings  
Remarks
b. Approved type SOA used
Location  
Findings  
Remarks
c. Electrical wires/hand tools are in good condition
Location  
Findings  
Remarks
d. Welding machine an other electrical equipments are earthed
Location  
Findings  
Remarks
e. Temporary electrical wiring system checked by LEW monthly
Location  
Findings  
Remarks
f. Socket outlet assembly (SOA) must be totally enclosed and locked with no live terminal or parts exposed
Location  
Findings  
Remarks

 

5. Oxygen – fuel gas equipment

a. Implementation of permit to work system – hot work
Location  
Findings  
Remarks
b. Gas cylinder kept in up-right position and kept at a safe distance from heat sources
Location  
Findings  
Remarks
c. Hose connections clamped or securely fastened. No jubilee clip shall be used as a hose clamping device
Location  
Findings  
Remarks
d. Flashback arrestor fitted at the pressure regulator outlet of every gas cylinder
Location  
Findings  
Remarks
e. Non return valve fitted wbetween each gas torch inlet an gas hose
Location  
Findings  
Remarks
f. Fire extinguisher provided
Location  
Findings  
Remarks

 

 

6. Authorized persons

A. Machinery operated by authorized/competent person
Location  
Findings  
Remarks
b. P/M Hoists examined by AP at least once in 6/3 months
Location  
Findings  
Remarks
c. Gondola/mast platform examined by AP at least 6/3 months
Location  
Findings  
Remarks

 

7. Hoisting operation

a. Approved signaler/rigger/liftingsupervisor/crance operator to comply with lifting regulation
Location  
Findings  
Remarks
b. lifting gear and appliance examined by AP at least once in every 12/6 months
Location  
Findings  
Remarks
c. Proper access preparation for cranes and corrrect hoisting procedures (access checked by engineer)
Location  
Findings  
Remarks

 

8. Excavation

a. Excavation checklist submitted
Location  
Findings  
Remarks
b. Ladder provided if excavation exceed 1.2 metres in depth
Location  
Findings  
Remarks
c. Excavated area adequately shored if it is more than 1.5 metres deep
Location  
Findings  
Remarks
d. Open sides of excavation effectively barricade if it is more tha 1.5 metres deep
Location  
Findings  
Remarks
e. Materials placed at least 610mm back from the edge of open excavation
Location  
Findings  
Remarks

 

9. Water pollution control

a. Slit laden/slit trap used to reduce slit content; discharging only fresh water into the drain
Location  
Findings  
Remarks
b. Vehicular truck slit, mud, etc washed before leaving the site
Location  
Findings  
Remarks

 

10. General housekeeping and vector control

a. Step on/tripping hazard eliminated
Location  
Findings  
Remarks
b. Materials placed at least 1m away from edge of building
Location  
Findings  
Remarks
c. Access free from obstruction
Location  
Findings  
Remarks
d. No water-bearing receptacles
Location  
Findings  
Remarks
e. Ground is leveled properly, no depression
Location  
Findings  
Remarks
f. Mosquitoes breeding ground elimnated
Location  
Findings  
Remarks
g. Routine vector control is carried out
Location  
Findings  
Remarks


11. Others: ______________